Year : 2022  |  Volume : 25  |  Issue : 4  |  Page : 525--527

Use of intraoperative coronary angiography to guide surgical intervention in coronary artery bypass graft surgery


Jaclyn H Mueller, Kimberly Hollander 
 Department of Anesthesiology, University of Maryland School of Medicine, Baltimore, MD, USA

Correspondence Address:
Jaclyn H Mueller
22 South Greene Street, Suite S11B, Baltimore, MD 21201
USA

Abstract

Following coronary artery bypass graft surgery, graft patency is a major factor contributing to patient morbidity and mortality. There are several modalities available for assessing graft patency intra-op used by both the anesthesiologist and surgeon. However, these modalities have their own advantages and disadvantages which will be summarized in this case report. As illustrated by this case, angiography continues to be the gold standard for coronary anatomy assessment and can be performed easily using a portable digital fluoroscopic system.



How to cite this article:
Mueller JH, Hollander K. Use of intraoperative coronary angiography to guide surgical intervention in coronary artery bypass graft surgery.Ann Card Anaesth 2022;25:525-527


How to cite this URL:
Mueller JH, Hollander K. Use of intraoperative coronary angiography to guide surgical intervention in coronary artery bypass graft surgery. Ann Card Anaesth [serial online] 2022 [cited 2023 Feb 1 ];25:525-527
Available from: https://www.annals.in/text.asp?2022/25/4/525/358122


Full Text



 Introduction



Coronary artery bypass graft surgery remains the cornerstone of treatment for coronary artery disease. Graft patency is a major factor contributing to cardiac morbidity and mortality, especially in the early follow-up period.[1] Intraoperative transesophageal echocardiography (TEE) and electrocardiogram (EKG) monitoring that are readily available in the operating room are sensitive for detecting clinically significant graft obstruction but are not specific. When there is high suspicion of bypass graft dysfunction, the ability to perform intraoperative angiography to assess graft patency should be considered to immediately identify obstructions and facilitate their prompt treatment, so the patient may leave with the optimal surgical result. IRB approval and clinical trial registration are not applicable and informed consent was obtained by the patient presented in the following case report.

 Case Report



A 51-year-old man with unstable angina was found to have severe single-vessel disease of the left anterior descending (LAD) artery and presented for minimally invasive direct coronary artery bypass (MIDCAB) surgery. Preoperative TEE showed normal biventricular function without valvular disease. Intraoperatively, the DaVinci robot (Intuitive, California USA) was used to dissect the left inferior mammary artery (LIMA) which had excellent flow when transected. The LAD was snared and a shunt was used to facilitate perfusion while the LIMA to LAD anastomosis was performed. ST elevations were noted during snaring of the LAD, but resolved immediately after finishing the LIMA to LAD anastomosis. However, when testing the patency with transit time flowmetry (TTFM) flow probes, they showed poor flow in the LIMA despite normalized ST segments and no regional wall motion abnormalities on TEE. The anastomosis was performed again with ST elevations during snaring that resolved after the anastomosis was completed. After re-anastomosis, flow probes again showed low flow through the LIMA without EKG or TEE changes. At this point, the decision was made to perform a sternotomy and the patient was cannulated for cardiopulmonary bypass. The mammary pedicle was mobilized and the LIMA was ligated and found to have brisk flow. With the heart arrested on cardiopulmonary bypass, the LIMA to LAD anastomosis was performed for a third time. The heart was reperfused and flow probes showed a flow of 110 mL/min with a pulsatility index of 1.0 in the LIMA-LAD. The patient came off bypass uneventfully. However, during chest closure, ST elevations were again seen on EKG monitoring without TEE changes. Upon re-checking with the flow probe, there was once again very low flow in the LIMA to LAD.

To further assess graft patency, an intraoperative coronary angiogram was performed using a portable digital fluoroscopic system. Intraoperative angiogram revealed flow in the LIMA, but no flow in the distal LAD, potentially due to a dynamic dissection flap at the anastomosis (see [Figure 1]). The patient was recannulated for cardiopulmonary bypass and a saphenous vein graft (SVG) was anastomosed to the distal LAD. Graft patency was confirmed with the flow probe showing adequate flow in the SVG-distal LAD and improved flow in the LIMA-LAD, and no further ST changes were noted.{Figure 1}

 Discussion



This case illustrates the utility of intraoperative angiography to promptly identify and precisely locate compromised graft patency even with less invasive modalities available. One such modality is transit time flow measurement (TTFM) which is based on the transit time of ultrasonic energy from two transducers in a probe passing through a liquid. While transit time flowmetry is noninvasive, simple, and relatively low cost, its measurements are dependent on a number of physical properties and hemodynamic parameters, including blood pressure, peripheral bed resistance, blood viscosity, and competitive flow, making standardization difficult and compromising diagnostic accuracy.[2] TTFM also has varying cut off values in order to determine abnormal flow. Currently most physicians use cutoff values of mean graft flow >20 mL/min and pulsatility index <5 for graft patency. However, most of this data are based on small cohorts and studies with differing cutoff values for predicting graft failure.[3],[4]

Another modality to assess graft patency includes epicardial ultrasound (ECUS) that is usually performed in conjunction with TTFM. ECUS is best performed on a resting heart and attempts to provide a more anatomical picture of the anastomosis and bypass graft. However, even on a resting heart, it is challenging to maintain stable and optimal contact with the ultrasound probe to assess patency without distorting the image. It is for this reason that ECUS has not gained widespread availability and is not accepted as standard practice.[5] Also, in this case, ECUS would not have been feasible during the first part of the MIDCAB procedure since probe placement would be technically improbable on a beating heart.

Intraoperative indocyanine green (ICG) imaging is another imaging technique that can be used intraoperatively to evaluate bypass grafts. Indocyanine green molecules bind to intravascular proteins securing their location in the vascular system. ICG is then stimulated by laser energy and emits a fluorescence light that is captured by a camera as it moves through the graft. The series of images that are captured are then compiled to create an angiographic representation of the vessel. In comparison to conventional angiography, ICG imaging provides high-quality images without the need for radiation or catheters. The limitations of ICG imaging are that it gives a derived image and it gives very little information on competitive flow, distal coronary bed, and transit times. Moreover, each graft requires 3-4 minutes which prolongs operative time.[6]

Although multiple modalities exist to assess graft patency intraoperatively, TTFM was used in this case, which highlights one of its most clinically relevant limitations. TTFM provides no anatomic information and cannot locate an obstruction, but rather only report if there is one present.[7] In this case, the ability to locate the obstruction distal to the anastomosis allowed the surgeon to effectively revise the graft and place a saphenous vein graft to the distal LAD. Thus, the patient was able to leave the operating room with an optimal surgical result.

Angiography continues to be the gold standard for coronary anatomy assessment. However, its routine intraoperative use is hindered by availability and portability, presence of ionizing radiation, time required, and cost. Thus, there is a need for less invasive intraoperative graft assessment modalities such as TTFM, and for many cases, such modalities are sufficient. However, intraoperative coronary angiography should be available in the event of clinically significant graft malfunctions (e.g., obstruction and vasospasm) that are not easily resolved as seen in the case presented. Such imaging could also be applied to other cardiac surgeries such as aortic root repairs where coronaries are reimplanted as well as mitral valve surgery where occlusion to the circumflex artery has been previously described.[8],[9]

The availability of hybrid cardiac suites is limited or unavailable at some hospitals. This case shows that angiography using a portable digital fluoroscopic system can be easily performed and provides immediate confirmation of graft patency. In summary, there is utility in intraoperative coronary angiography in selected cases in order to promptly diagnose and guide surgical revision in coronary bypass grafting when other modalities are limited.

Declaration of patient consent

The authors certify that they have obtained all appropriate patient consent forms. In the form the patient (s) has/have given his/her/their consent for his/her/their images and other clinical information to be reported in the journal. The patients understand that their names and initials will not be published and due efforts will be made to conceal their identity, but anonymity cannot be guaranteed.

Acknowledgements

No other acknowledgements for contributions, technical help or financial and/or material support.

Informed consent

The patient's informed written consent was obtained for publication of this case report.

Financial support and sponsorship

Nil.

Conflicts of interest

There are no conflicts of interest.

References

1Kieser TM, Rose S, Kowalewski R, Belenkie I. Transit-time flow predicts outcomes in coronary artery bypass graft patients: A series of 1000 consecutive arterial grafts. Eur J Cardiothorac Surg 2010;38:155-62.
2di Giammarco G, Pano M, Cirmeni S, Pelini P, Vitolla G, di Mauro M. Predictive value of intraoperative transit-time flow measurement for short-term graft patency in coronary surgery. J Thorac Cardiovasc Surg 2006;132:468-74.
3Niclauss L. Techniques and standards in intraoperative graft verification by transit time flow measurement after coronary artery bypass graft surgery: A critical review. Eur J Cardiothorac Surg 2017;51:26-33.
4Quin J, Lucke J, Hattler B, Gupta S, Baltz J, Bishawi M, et al. Surgeon judgment and utility of transit time flow probes in coronary artery bypass grafting surgery. JAMA Surg 2014;149:1182-7.
5Akhrass R, Bakaeen FG. Intraoperative graft patency validation: Friend or foe? JTCVS Tech 2021;7:131-7.
6Ohmes LB, Di Franco A, Di Giammarco G, Rosati CM, Lau C, Girardi LN, et al. Techniques for intraoperative graft assessment in coronary artery bypass surgery. J Thorac Dis 2017;9:S327-32.
7Leacche M, Balaguer JM, Byrne JG. Intraoperative grafts assessment. Semin Thorac Cardiovasc Surg 2009;21:207-12.
8Hiltrop N, Bennett J, Desmet W. Circumflex coronary artery injury after mitral valve surgery: A report of four cases and comprehensive review of the literature. Catheter Cardiovasc Interv 2017;89:78-92.
9Westaby S, Katsumata T, Vaccari G. Aortic root replacement with coronary button re-implantation: Low risk and predictable outcome. Eur J Cardiothorac Surg 2000;17:259-65.